Product : ISaGRAF 3 (Sources files for VxWorks)
Date : 27-August-1997
File : VxWorks.How to compile ISaGRAF VxWorks sources for Intel.htm
Subject : How to compile ISaGRAF VxWorks sources for Intel
Keywords: VxWorks - VxWorks on Intel
____________________________________________________________________
In order to re-compile all VxWorks sources files for a VxWorks
INTEL target, you need to:
- modify tasy0def.h for Intel target as it is described in "IDK guide"
in chapter "Souce files to be completed"
"TASY0DEF.H system definition file" (there are some definitions to keep
and other ones to remove)
- modify 'makedefs' file.
This file is used by all compilation batch files, and, if you
have Tornado as cross development tool, it is the only one that
needs to be modified.
In 'makedefs', the main elements to change are the following:
. CPU= // the CPU name has to be changed
. you must change the compiler optimisation
. CC= cc68K // the compiler name has to be changed
. LD= //the linker name has to be changed
See again IDK guide, but this time in chapter
"Task generation: generic makefiles"
- if you want to be able to save your downloaded application to
the hard disk, you need to set a pathName in TSK_FUNIT (in .spt
files) as described in target manuel, in chapter "getting
started with VxWorks target" "Application backup file storage
unit"
____________________________________________________________________
Copyright © 1996-2009 ICS Triplex ISaGRAF Inc. All rights reserved.